Radionuclide Identification Devices (RIDs):

PM1401K-3P Multipurpose Hand-Held Radiation Monitor/Identifier

PM1401K-3 series of radiation monitors compromises a wide range of all-in-one devices for radiation detection, dose rate and contamination measurements, spectrometry and radionuclide identification.

PM1401K-3P model is the most advanced model in the series suitable for various radiation control tasks including measurement of ambient dose equivalent rate, detection of alpha, beta, gamma and neutron sources, measurement of alpha and beta radiation flux density, acquisition of gamma spectra, identification of radioisotopes, and measurement of food/soil contamination with 137Cs.

Operation principle

PM1401K-3P continuously measures ambient dose equivalent rate Ḣ*(10) of photon radiation in the wide energy range, detects alpha, beta, gamma and neutron radiation, measures alpha and beta radiation flux density, operates as a gamma radiation spectrometer and radioisotope identifier, and measures food/soil contamination with 137Cs radionuclide.

Models

  • РМ1401K-3P is the most versatile gamma-neutron model in the series suitable for various radiation control tasks including measurement of ambient dose equivalent rate, detection of alpha, beta, gamma and neutron sources, measurement of alpha and beta radiation flux density, acquisition of gamma spectra, identification of radioisotopes, and measurement of food/soil contamination with 137Cs.
  • PM1401K-3E is a simplified gamma-neutron model without identification and 137Cs activity measurement functions.
  • РМ1401K-3М is a gamma-only analog of the PM1401K-3P model with the same functionality, except for neutron detection.
  • РМ1401К-3PM is a gamma-neutron model with improved search and identification algorithms, ambient dose equivalent measurement functionality and a Bluetooth module for wireless transfer of the acquired gamma spectra. Does not have alpha and beta radiation search and measurement and 137Cs activity measurement functions.

Features

  • Storage of up to 10000 events and 1000 spectra
  • Audible, visual and external vibration alarm
  • Categorization of identified radionuclides
  • Shock and water resistant IP65 case
  • Adjustable radionuclide libraries
  • USB communication with PC
  • Built-in GPS module

Applications

  • Customs and border control
  • HAZMAT and CBRNe teams
  • Emergency services
  • Police and security
  • Industrial facilities
  • First responders

Specifications:

Detectorgamma neutronCsl(TI); GM counter 6LiF/ZnS
Gamma sensitivityfor 137Cs for 241Am200 cps per µSv/h 2000 cps per µSv/h
Neutron sensitivityfor Pu-a-Be for thermal neutrons0.15 cps⋅cm2 5.0 cps⋅cm2
Energy rangegamma (spectroscopy) gamma (measurement) neutron25 keV to 3 MeV 15 keV to 15 MeV thermal to 14 MeV
Dose rate measurement range0.1 µSv/h to 100 mSv/h
Dose rate measurement accuracy±(15 + 0.0015 / Ḣ) %,
where Ḣ is the measured dose equivalent rate value in mSv/h
Resolution≤ 9 % FWHM at 0.662 MeV (137Cs)
Gamma radiation scintillation spectra acquisition1024 channels
Radionuclide library3 extensible and editable libraries (ANSI N42.34 compliant, IND, MED, NORM, SNM categorization)
Flux density measurement rangealpha beta15 to 105 min-1·cm-2 6 to 105 min-1·cm-2
137Cs activity measurement range102 to 105 Bq/kg (Bq/l)
Warm-up time< 90 s
Memory10000 events, 1000 spectra
Alarmsvisual, audible, external vibration
CommunicationUSB
Power supply2 AA alkaline or NiMH batteries
Battery lifetime (normal radiation background, active alarms and LCD backlight < 5 min/24 h)≥ 300 h
Ingress protectionIP65
Drop test0.7 m
Dimensions262 × 60 × 65 mm
Weight≤ 820 g
Operating conditions
ambient temperature
atmospheric pressure
relative humidity

–20 °C to 50 °C
84 kPa to 106.7 kPa
up to 95 % at 35 °C
PM1401K-3M Multipurpose Hand-Held Radiation Monitor/Identifier

PM1401K-3 series of radiation monitors compromises a wide range of all-in-one devices for radiation detection, dose rate and contamination measurements, spectrometry and radionuclide identification.

PM1401K-3M model is a gamma-only radiation monitor without a neutron detector. The instrument is designed for quick and reliable measurement of gamma dose rate, detection of alpha, beta, and gamma sources, measurement of alpha and beta radiation flux density, acquisition of gamma spectra, identification of radioisotopes, and measurement of food/soil contamination with 137Cs.

Operation principle

PM1401K-3M continuously measures ambient dose equivalent rate Ḣ*(10) of photon radiation in the wide energy range, detects alpha, beta and gamma radiation, measures alpha and beta radiation flux density, operates as a gamma radiation spectrometer and radioisotope identifier, and measures food/soil contamination with 137Cs radionuclide.

Models

  • РМ1401K-3P is the most versatile gamma-neutron model in the series suitable for various radiation control tasks including measurement of ambient dose equivalent rate, detection of alpha, beta, gamma and neutron sources, measurement of alpha and beta radiation flux density, acquisition of gamma spectra, identification of radioisotopes, and measurement of food/soil contamination with 137Cs.
  • PM1401K-3E is a simplified gamma-neutron model without identification and 137Cs activity measurement functions.
  • РМ1401K-3М is a gamma-only analog of the PM1401K-3P model with the same functionality, except for neutron detection.
  • РМ1401К-3PM is a gamma-neutron model with improved search and identification algorithms, ambient dose equivalent measurement functionality and a Bluetooth module for wireless transfer of the acquired gamma spectra. Does not have alpha and beta radiation search and measurement and 137Cs activity measurement functions.

Features

  • Storage of up to 10000 events and 1000 spectra
  • Audible, visual and external vibration alarm
  • Categorization of identified radionuclides
  • Shock and water resistant IP65 case
  • Adjustable radionuclide libraries
  • USB communication with PC
  • Built-in GPS module

Applications

  • Customs and border control
  • HAZMAT and CBRNe teams
  • Emergency services
  • Police and security
  • Industrial facilities
  • First responders

Specifications:

DetectorCsl(TI); GM counter
Gamma sensitivityfor 137Cs for 241Am200 cps per µSv/h 2000 cps per µSv/h
Energy rangegamma (spectroscopy) gamma (measurement)25 keV to 3 MeV 15 keV to 15 MeV
Dose rate measurement range0.1 µSv/h to 100 mSv/h
Dose rate measurement accuracy±(15 + 0.0015 / Ḣ) %,
where Ḣ is the measured dose equivalent rate value in mSv/h
Resolution≤ 9 % FWHM at 0.662 MeV (137Cs)
Gamma radiation scintillation spectra acquisition1024 channels
Radionuclide library3 extensible and editable libraries (ANSI N42.34 compliant, IND, MED, NORM, SNM categorization)
Flux density measurement rangealpha beta15 to 105 min-1·cm-2 6 to 105 min-1·cm-2
137Cs activity measurement range102 to 105 Bq/kg (Bq/l)
Warm-up time< 90 s
Memory10000 events, 1000 spectra
Alarmsvisual, audible, external vibration
CommunicationUSB
Power supply2 AA alkaline or NiMH batteries
Battery lifetime (normal radiation background, active alarms and LCD backlight < 5 min/24 h)≥ 300 h
Ingress protectionIP65
Drop test0.7 m
Dimensions262 × 60 × 65 mm
Weight≤ 820 g
Operating conditions
ambient temperature
atmospheric pressure
relative humidity

–20 °C to 50 °C
84 kPa to 106.7 kPa
up to 95 % at 35 °C

Personal Radiation Detectors (PRDs):

PM1703MA-II/BT Personal Radiation Detector

Overview:

PM1703-II series of personal radiation detectors (PRDs) are extremely sensitive and robust devices that detect and locate even trace amounts of radioactive materials.

Equipped with a clip for multiple wearing options and easy to operate even for non-specialists, PRDs became the perfect fit as Radiation Pagers for public security agencies, including border control, rescue teams, police and anti-terrorist units that need to quickly search for radioactive materials in public places.

PM1703MA-II models are gamma-only PRDs equipped with a high-sensitive scintillator for measurement of the personal dose rate up to 300 µSv/h. PM1703MA–II BT model in addition has a Bluetooth module that enables communication with smartphones for advanced operation via the free Polismart® App.

Operation principle

PM1703MA-II models are gamma-only PRDs equipped with a high-sensitive scintillator for measurement of the personal dose rate up to 300 µSv/h. While ensuring high-performance detection for any scenario, PM1703-II PRD provides confidence in personal safety by continuously monitoring the measured dose equivalent rate and alerting the user with visual, audible and vibration alarms when the pre-set radiation thresholds are exceeded.

Operating history is stored in the instrument‘s non-volatile memory (up to 2000 data points), protecting the data even when the battery is removed. The stored data can also be transferred to a PC via USB. Storing data format is designed to meet the ANSI N42.42.

The PRD features a dedicated operation mode “Mode 0…9” specifically designed for monitoring gamma radiation dose rate within a numerical range. This mode is particularly user-friendly, making it easier for non-professionals to understand and navigate.

Polimaster PRDs offer a significant advantage with their NORM suppression algorithm. This algorithm differentiates alarm signals when there is an increase in natural gamma background values and detection of Naturally Occurring Radioactive Materials (NORM). When NORMs are detected, a green indication light is displayed. However, if other radionuclide types (IND, NUC, MED) are detected, a red indication light and sound alarm are activated. This feature ensures clear and distinct indications based on the specific type of radiation detected.

Models

  • PM1703MA-II PRD is a basic model.
  • PM1703MA–II BT PRD is additionally equipped with a Bluetooth module that enables communication with smartphones for advanced operation via the free Polismart® Android App.

Features

  • NORM-suppression algorithm for differentiating color-coded alarms triggered by natural or man-made radiation materials
  • Dedicated 0-9 scale mode with unitless dose rate indication allowing for ease of use and minimal training
  • Free Polismart® iOS and Android app for advanced operation 
  • USB and Bluetooth (PM1703MA-II BT) communication
  • Long-life alkaline or rechargeable battery
  • Audible, visual and vibration alarms 
  • USB and Bluetooth communication
  • Shockproof hermetic case IP65

Applications

  • Customs and border control
  • HAZMAT and CBRNe teams
  • Steel and recycling industry
  • Waste management sites
  • Counter terrorism teams
  • Homeland security
  • First responders
  • Special forces
  • Public safety

Specifications:

DetectorCsl(TI) SiPM
Gamma sensitivity100 cps per µSv/h 500 cps per µSv/h
Energy rangegamma (search) gamma (measurement)33 keV to 3 MeV 60 keV to 1.33 MeV
Count rate indication range1 to 9999 cps
Dose rate measurement range0.1 µSv/h to 300 µSv/h
Dose rate measurement accuracy±30 %
Response time0.25 s
Memory2000 events
Alarmsvisual, audible, vibration
CommunicationUSB; Bluetooth 4.0 (PM1703MA-IIBT) (FCC ID: QOQBLE112, IC: 5123A-BGTBLE112)
Power supplyone AA (LR6) alkaline or rechargeable battery
Battery lifetime≥ 1000 hours (Bluetooth off) ≥ 500 hours (Bluetooth on)
Ingress protectionIP65
Drop test0.7 m
Dimensions87 × 72 × 32 mm
Weight≤ 200 g
Operating conditions
ambient temperature
atmospheric pressure
relative humidity

–40 °C to 50 °C
84 kPa to 106.7 kPa
up to 98 % at 35 °C
Standards complianceANSI N42.32-2016, IEC 62401:2017
PM1703MO-II BT Personal Radiation Detector/Dosimeter

Overview:

PM1703-II series of personal radiation detectors (PRDs) are extremely sensitive and robust devices that detect and locate even trace amounts of radioactive materials.

Equipped with a clip for multiple wearing options and easy to operate even for non-specialists, PRDs became the perfect fit as Radiation Pagers for public security agencies, including border control, rescue teams, police and anti-terrorist units that need to quickly search for radioactive materials in public places. 

PM1703MO–II BT model is a gamma-only PRD/dosimeter equipped with a high-sensitive scintillator and a Geiger-Mueller counter for extended measurement of the personal dose rate up to 200 mSv/h and personal dose up to 10 Sv. This model also has a Bluetooth module that enables communication with smartphones for advanced operation via the free Polismart® App.

Operation principle

PM1703MO-II BT is a gamma-only PRD/dosimeter equipped with a high-sensitive scintillator and a Geiger-Mueller counter for extended measurement of the personal dose rate up to 200 mSv/h and personal dose up to 10 Sv. While ensuring high-performance detection for any scenario, PM1703-II PRD provides confidence in personal safety by continuously monitoring the measured dose equivalent rate and alerting the user with visual, audible and vibration alarms when the pre-set radiation thresholds are exceeded.

Operating history is stored in the instrument‘s non-volatile memory (up to 2000 data points), protecting the data even when the battery is removed. The stored data can also be transferred to a PC via USB. Storing data format is designed to meet the ANSI N42.42.

The PRD features a dedicated operation mode “Mode 0…9” specifically designed for monitoring gamma radiation dose rate within a numerical range. This mode is particularly user-friendly, making it easier for non-professionals to understand and navigate.

Polimaster PRDs offer a significant advantage with their NORM suppression algorithm. This algorithm differentiates alarm signals when there is an increase in natural gamma background values and detection of Naturally Occurring Radioactive Materials (NORM). When NORMs are detected, a green indication light is displayed. However, if other radionuclide types (IND, NUC, MED) are detected, a red indication light and sound alarm are activated. This feature ensures clear and distinct indications based on the specific type of radiation detected.

Features

  • Personal dose accumulation up to 10 Sv
  • Extended dose rate measurement range up to 200 mSv/h
  • NORM-suppression algorithm for differentiating color-coded alarms triggered by natural or man-made radiation materials
  • Free Polismart® iOS and Android app for advanced operation 
  • USB and Bluetooth communication
  • Long-life alkaline or rechargeable battery
  • Audible, visual and vibration alarms 
  • Shockproof hermetic case IP65

Applications

  • Customs and border control
  • HAZMAT and CBRNe teams
  • Steel and recycling industry
  • Waste management sites
  • Counter terrorism teams
  • Homeland security
  • First responders
  • Special forces
  • Public safety

Specifications:

DetectorCsl(TI) SiPM;  GM counter
Gamma sensitivityfor 137Cs for 241Am100 cps per µSv/h 500 cps per µSv/h
Energy rangegamma (search) gamma (measurement)33 keV to 3.0 MeV 60 keV to 1.33 MeV
Dose rate measurement range0.1 µSv/h to 200 mSv/h
Dose rate measurement accuracy±(20+0.0025/Ḣ) %,
where Ḣ is the measured dose rate value in mSv/h
Dose measurement range0.1 µSv to 10 Sv
Dose measurement accuracy±20 %
Response time0.25 s
Memory2000 events
Alarmsvisual, audible, vibration
CommunicationUSB; Bluetooth 4.0 (FCC ID: QOQBLE112, IC: 5123A-BGTBLE112)
Power supplyone AA (LR6) alkaline or rechargeable battery
Battery lifetime≥ 1000 hours (Bluetooth off) ≥ 500 hours ( Bluetooth on)
Ingress protectionIP65
Drop test0.7 m
Dimensions87 × 72 × 32 mm
Weight≤ 200 g
Operating conditions
ambient temperature
atmospheric pressure
relative humidity
 
–40 °C to 50 °C
84 kPa to 106.7 kPa
up to 98 % at 35 °C
Standards complianceANSI N42.32-2016, IEC 62401:2017
PM1703GNA-II/BT Personal Radiation Detector

Overview:

PM1703-II series of personal radiation detectors (PRDs) are extremely sensitive and robust devices that detect and locate even trace amounts of radioactive materials.

Equipped with a clip for multiple wearing options and easy to operate even for non-specialists, PRDs became the perfect fit as Radiation Pagers for public security agencies, including border control, rescue teams, police and anti-terrorist units that need to quickly search for radioactive materials in public places.

PM1703GNA-II models are gamma-neutron PRDs equipped with a high-sensitive scintillator for measurement of the personal dose rate up to 300 µSv/h.

PM1703GNA–II BT model in addition has a Bluetooth module that enables communication with smartphones for advanced operation via the free Polismart® App.

Operation principle

PM1703GNA-II models are gamma-neutron PRDs equipped with a high-sensitive scintillator for measurement of the personal dose rate up to 300 µSv/h. While ensuring high-performance detection for any scenario, PM1703-II PRD provides confidence in personal safety by continuously monitoring the measured dose equivalent rate and alerting the user with visual, audible and vibration alarms when the pre-set radiation thresholds are exceeded.

Operating history is stored in the instrument‘s non-volatile memory (up to 2000 data points), protecting the data even when the battery is removed. The stored data can also be transferred to a PC via USB. Storing data format is designed to meet the ANSI N42.42.

The PRD features a dedicated operation mode “Mode 0…9” specifically designed for monitoring gamma radiation dose rate within a numerical range. This mode is particularly user-friendly, making it easier for non-professionals to understand and navigate.

Polimaster PRDs offer a significant advantage with their NORM suppression algorithm. This algorithm differentiates alarm signals when there is an increase in natural gamma background values and detection of Naturally Occurring Radioactive Materials (NORM). When NORMs are detected, a green indication light is displayed. However, if other radionuclide types (IND, NUC, MED) are detected, a red indication light and sound alarm are activated. This feature ensures clear and distinct indications based on the specific type of radiation detected.

Models

  • PM1703GNA-II PRD is a basic model.
  • PM1703GNA–II BT PRD is additionally equipped with a Bluetooth module that enables communication with smartphones for advanced operation via the free Polismart® Android App.
  • PM1703GNA–II MBT PRD/Dosimeter is additionally equipped with a Bluetooth module and a Geiger-Mueller counter for extended measurement of the personal dose rate up to 200 mSv/h and personal dose up to 10 Sv.

Features

  • NORM-suppression algorithm for differentiating color-coded alarms triggered by natural or man-made radiation materials
  • Dedicated 0-9 scale mode with unitless dose rate indication allowing for ease of use and minimal training
  • Free Polismart® iOS and Android app for advanced operation 
  • USB and Bluetooth (PM1703GNA-II BT) communication
  • Long-life alkaline or rechargeable battery
  • Audible, visual and vibration alarms 
  • Shockproof hermetic case IP65

Applications

  • Customs and border control
  • HAZMAT and CBRNe teams
  • Steel and recycling industry
  • Waste management sites
  • Counter terrorism teams
  • Homeland security
  • First responders
  • Special forces
  • Public safety

Specifications:

Detectorgamma neutronCsl(TI) SiPM 6LiF/ZnS
Gamma sensitivityfor 137Cs for 241Am100 cps per µSv/h 500 cps per µSv/h
Neutron sensitivityfor Pu-a-Be for thermal neutrons0.035 counts × cm2/neutron 1.2 counts × cm2/neutron
Energy rangegamma (search) gamma (measurement) neutron33 keV to 3.0 MeV 60 keV to 1.33 MeV thermal to 14.0 MeV
Count rate indication rangegamma neutron1 to 9999 cps 1 to 999 cps
Dose rate measurement range0.1 µSv/h to 300 µSv/h
Dose rate measurement accuracy±30 %
Response time0.25 s
Memory2000 events
Alarmsvisual, audible, vibration
CommunicationUSB; Bluetooth 4.0 (PM1703GNA-IIBT) (FCC ID: QOQBLE112, IC: 5123A-BGTBLE112)
Power supplyone AA (LR6) alkaline or rechargeable battery
Battery lifetime  ≥ 800 hours (Bluetooth off) ≥ 400 hours ( Bluetooth on)
Ingress protectionIP65
Drop test0.7 m
Dimensions87 × 72 × 32 mm
Weight≤ 200 g
Operating conditions
ambient temperature
atmospheric pressure
relative humidity
 
–40 °C to 50 °C
84 kPa to 106.7 kPa
up to 98 % at 35 °C
Standards complianceANSI N42.32-2016,
IEC 62401:2017
PM1703GNA-II MBT Personal Radiation Detector/Dosimeter

Overview:

PM1703-II series of personal radiation detectors (PRDs) are extremely sensitive and robust devices that detect and locate even trace amounts of radioactive materials.

Equipped with a clip for multiple wearing options and easy to operate even for non-specialists, PRDs became the perfect fit as Radiation Pagers for public security agencies, including border control, rescue teams, police and anti-terrorist units that need to quickly search for radioactive materials in public places.

PM1703GNA–II MBT model is a gamma-neutron PRD/dosimeter equipped with a high-sensitive scintillator and a Geiger-Mueller counter for extended measurement of the personal dose rate up to 200 mSv/h and personal dose up to 10 Sv. This model also has a Bluetooth module that enables communication with smartphones for advanced operation via the free Polismart® App.

Operation principle

PM1703GNA-II MBT is a gamma-neutron PRD/dosimeter equipped with a high-sensitive scintillator and a Geiger-Mueller counter for extended measurement of the personal dose rate up to 200 mSv/h and personal dose up to 10 Sv. While ensuring high-performance detection for any scenario, PM1703-II PRD provides confidence in personal safety by continuously monitoring the measured dose equivalent rate and alerting the user with visual, audible and vibration alarms when the pre-set radiation thresholds are exceeded.

Operating history is stored in the instrument‘s non-volatile memory (up to 2000 data points), protecting the data even when the battery is removed. The stored data can also be transferred to a PC via USB. Storing data format is designed to meet the ANSI N42.42.

The PRD features a dedicated operation mode “Mode 0…9” specifically designed for monitoring gamma radiation dose rate within a numerical range. This mode is particularly user-friendly, making it easier for non-professionals to understand and navigate.

Polimaster PRDs offer a significant advantage with their NORM suppression algorithm. This algorithm differentiates alarm signals when there is an increase in natural gamma background values and detection of Naturally Occurring Radioactive Materials (NORM). When NORMs are detected, a green indication light is displayed. However, if other radionuclide types (IND, NUC, MED) are detected, a red indication light and sound alarm are activated. This feature ensures clear and distinct indications based on the specific type of radiation detected.

Models

  • PM1703GNA-II PRD is a basic model.
  • PM1703GNA–II BT PRD is additionally equipped with a Bluetooth module that enables communication with smartphones for advanced operation via the free Polismart® Android App.
  • PM1703GNA–II MBT PRD/Dosimeter is additionally equipped with a Bluetooth module and a Geiger-Mueller counter for extended measurement of the personal dose rate up to 200 mSv/h and personal dose up to 10 Sv.

Features

  • Personal dose accumulation up to 10 Sv
  • Extended dose rate measurement range up to 200 mSv/h
  • NORM-suppression algorithm for differentiating color-coded alarms triggered by natural or man-made radiation materials
  • Dedicated 0-9 scale mode with unitless dose rate indication allowing for ease of use and minimal training
  • Free Polismart® iOS and Android app for advanced operation 
  • USB and Bluetooth communication
  • Long-life alkaline or rechargeable battery
  • Audible, visual and vibration alarms 
  • Shockproof hermetic case IP65

Applications

  • Customs and border control
  • HAZMAT and CBRNe teams
  • Steel and recycling industry
  • Waste management sites
  • Counter terrorism teams
  • Homeland security
  • First responders
  • Special forces
  • Public safety

Specifications:

Detectorgamma neutronCsl(TI) SiPM;  GM counter 6LiF/ZnS
Gamma sensitivityfor 137Cs for 241Am100 cps per µSv/h 500 cps per µSv/h
Neutron sensitivityfor Pu-a-Be for thermal neutrons0.035 counts × cm2/neutron 1.2 counts × cm2/neutron
Energy rangegamma (search) gamma (measurement) neutron33 keV to 3.0 MeV 60 keV to 1.33 MeV thermal to 14.0 MeV
Count rate indication rangegamma neutron1 to 9999 cps 1 to 999 cps
Dose rate measurement range0.1 µSv/h to 200 mSv/h
Dose rate measurement accuracy±30 %
Dose measurement range0.1 µSv to 10 Sv
Dose measurement accuracy±30 %
Response time0.25 s
Memory2000 events
Alarmsvisual, audible, vibration
CommunicationUSB; Bluetooth 4.0 (FCC ID: QOQBLE112, IC: 5123A-BGTBLE112)
Power supplyone AA (LR6) alkaline or rechargeable battery
Battery lifetime  ≥ 800 hours (Bluetooth off) ≥ 400 hours (Bluetooth on)
Ingress protectionIP65
Drop test0.7 m
Dimensions99 × 75 × 36 mm
Weight≤ 240 g
Operating conditions
ambient temperature
atmospheric pressure
relative humidity
 
–40 °C to 50 °C
84 kPa to 106.7 kPa
up to 98 % at 35 °C
Standards complianceANSI N42.32-2016,
IEC 62401:2017

X-ray and Gamma Radiation Dosimeters

PM1610 X-Ray and Gamma Radiation Personal Dosimeter

Overview:

PM1610 series of electronic personal dosimeters (EPDs) are intended for measurement of the personal dose equivalent Hp(10) and personal dose equivalent rate Ḣp(10). The dosimeters are suitable for multiple applications providing the measurement of X-ray (continuous and pulsed) and gamma radiation in the wide energy range.

PM1610 dosimeters have unique features for operation in workplaces requiring the use of personal protective equipment or a harsh environment, including a shockproof rubberized case, a high contrast display with a fluorescent backlight, and two big buttons for easy use even while wearing protective gloves.

Operation principle

PM1610 EPDs allow the setting of two dose rate alarm thresholds and two dose alarm thresholds. The instruments continuously control the threshold levels and alert the user with audible, visual and vibration alarms when the threshold levels are exceeded. PM1610 automatically records and stores in its non-volatile memory up to 7500 dose rate and dose measurement history events.

The dosimeter is manufactured in two models: the basic PM1610 model and the PM1610A model with an extended dose measurement range of up to 20 Sv and improved accuracy of the dose rate measurement.

EPD is supplied with the user software for downloading measurement history to a PC, maintaining personnel exposure database and adjusting the settings of the dosimeter. PM1610 dosimeters are also compatible with PM530 Automated Personal Dosimetry System for maintaining the instrument history database and monitoring personnel exposure.

Features

  • Long-life rechargeable battery: at least 650 hours
  • Extended energy range: from 20 keV to 10 MeV
  • Wide dose and dose rate measurement ranges
  • Measurement of pulsed photon radiation
  • Simple navigation with two large buttons
  • Audible, visual and vibration alarms
  • USB communication with PC
  • Shockproof hermetic case
  • Small and lightweight

Applications

  • Customs and border control
  • Healthcare professionals
  • Nuclear power plants
  • Emergency services
  • Police and security
  • Industrial facilities
  • First responders

Specifications:

DetectorGeiger-Mueller tube
Dose rate measurement range0.1 µSv/h to 10 Sv/h
Dose rate measurement accuracy±(15+0.0015/Ḣ) % for PM1610 ±(10+0.0015/Ḣ+0.0015∙Ḣ) % for PM1610A where Ḣ is the measured dose rate value in mSv/h
Dose measurement range continuous photon radiationpulsed photon radiation  0.05 µSv to 10 Sv (up to20 Sv for PM1610A) 10 µSv to 10 Sv (up to20 Svfor PM1610A)
Dose measurement accuracy±20 %
Energy range20 keV to 10 MeV
Energy response relative to 0.662 MeV (137Cs)–60 % (20 keV to 33 keV) –40 % (33 keV to 48 keV) ±30 % (48 keV to 3 MeV) ±50 % (3 MeV to 10 MeV)
Minimum pulse duration of pulsed X-ray radiation1 ms
Memory7500 events
Alarmsvisual, audible, vibration
CommunicationUSB
Power supplybuilt-in rechargeable battery; external via USB
Battery lifetime (average dose rate < 0.3 µSv/h, active alarms < 20 s / 24 h)≥ 650 hours
Ingress protectionIP65
Drop test1.5 m
Dimensions≤ 58 × 59 × 20 mm
Weight≤ 70 g
Operating conditions
ambient temperature
atmospheric pressure
relative humidity
 
–20 °C to 50 °C
84 kPa to 106.7 kPa
up to 98 % at 35 °C
PM1610A X-Ray and Gamma Radiation Personal Dosimeter

Overview:

PM1610 series of electronic personal dosimeters (EPDs) are intended for measurement of the personal dose equivalent Hp(10) and personal dose equivalent rate Ḣp(10). The dosimeters are suitable for multiple applications providing the measurement of X-ray (continuous and pulsed) and gamma radiation in the wide energy range.

PM1610 dosimeters have unique features for operation in workplaces requiring the use of personal protective equipment or a harsh environment, including a shockproof rubberized case, a high contrast display with a fluorescent backlight, and two big buttons for easy use even while wearing protective gloves.

Operation principle

PM1610 EPDs allow the setting of two dose rate alarm thresholds and two dose alarm thresholds. The instruments continuously control the threshold levels and alert the user with audible, visual and vibration alarms when the threshold levels are exceeded. PM1610 automatically records and stores in its non-volatile memory up to 7500 dose rate and dose measurement history events.
The dosimeter is manufactured in two models: the basic PM1610 model and the PM1610A model with an extended dose measurement range of up to 20 Sv and improved accuracy of the dose rate measurement. 
EPD is supplied with the user software for downloading measurement history to a PC, maintaining personnel exposure database and adjusting the settings of the dosimeter. PM1610 dosimeters are also compatible with PM530 Automated Personal Dosimetry System for maintaining the instrument history database and monitoring personnel exposure.

Features

  • Long-life rechargeable battery: at least 650 hours
  • Extended energy range: from 20 keV to 10 MeV
  • Wide dose and dose rate measurement ranges
  • Measurement of pulsed photon radiation
  • Simple navigation with two large buttons
  • Audible, visual and vibration alarms
  • USB communication with PC
  • Shockproof hermetic case
  • Small and lightweight

Applications

  • Customs and border control
  • Healthcare professionals
  • Nuclear power plants
  • Emergency services
  • Police and security
  • Industrial facilities
DetectorGeiger-Mueller tube
Dose indication range0.001 μSv to 24 Sv
Dose measurement range0.05 µSv to 20 Sv (continuous photon radiation)
10 µSv to 20 Sv (pulsed photon radiation)

Dose measurement accuracy± 20 %
Dose rate indication range0.01 µSv/h to 12 Sv/h
Dose rate measurement range0.1 µSv/h to 10 Sv/h
Dose rate measurement accuracy± (10 +0.0015 / Ḣ + 0.0015 ∙ Ḣ )%, where Ḣ is the measured dose rate value in mSv/h

Minimum pulse duration of pulsed X-ray radiation1 ms
Energy range20 keV to 10 MeV
Energy response relative to 0.662 MeV (137Cs)−60 % (20 keV to 33 keV)
−40 % (33 keV to 48 keV)
±30 % (48 keV to 3 MeV)
±50 % (3 MeV to 10 MeV)

Alarmsvisual, audible, vibration
Thresholds2 independent thresholds for both dose and dose rate
Memory7500 events
PC communicationUSB
Power supplybuilt-in rechargeable battery
Battery lifetime650 hours*
*when the average dose rate is not more than 0.3 µSv/h; backlight and alarms are activated for not more than 20 s per 24 hours

Ingress protectionIP65
Drop test1.5 m onto hard wooden surface
Dimensions58 × 59 × 20 mm
Weight70 g
Operating temperature–20 °С to 50 °С
Atmospheric pressure84 to 106.7 kPa
Humidity98 % at 35 °С
Mean recovery time60 min
Mean service lifetime10 years
PM1610B X-Ray and Gamma Radiation Personal Dosimeter

Overview:

PM1610 series of electronic personal dosimeters (EPDs) are intended for measurement of the personal dose equivalent Hp(10) and personal dose equivalent rate Ḣp(10). The dosimeters are suitable for multiple applications providing the measurement of X-ray (continuous and pulsed) and gamma radiation in the wide energy range.

PM1610B model has an extended dose measurement range up to 20 Sv and improved accuracy of the dose rate measurement. Instead of a rechargeable battery, this model is powered by AAA (LR03) battery which is easy to replace, affordable and safe to handle.

PM1610 dosimeters have unique features for operation in workplaces requiring the use of personal protective equipment or a harsh environment, including a shockproof rubberized case, a high contrast display with a fluorescent backlight, and two big buttons for easy use even while wearing protective gloves.

Operation principle

PM1610 EPDs allow the setting of two dose rate alarm thresholds and two dose alarm thresholds. The instruments continuously control the threshold levels and alert the user with audible, visual and vibration alarms when the threshold levels are exceeded. PM1610 automatically records and stores in its non-volatile memory up to 7500 dose rate and dose measurement history events.

EPD is supplied with the user software for downloading measurement history to a PC, maintaining personnel exposure database and adjusting the settings of the dosimeter. PM1610 dosimeters are also compatible with PM530 Automated Personal Dosimetry System for maintaining the instrument history database and monitoring personnel exposure.

Features

  • Easily replaceable long-life AAA battery: at least 480 hours
  • Extended energy range: from 20 keV to 10 MeV
  • Wide dose and dose rate measurement ranges
  • Measurement of pulsed photon radiation
  • Simple navigation with two large buttons
  • Audible, visual and vibration alarms
  • USB communication with PC
  • Shockproof hermetic case
  • Small and lightweight

Applications

  • Customs and border control
  • Healthcare professionals
  • Nuclear power plants
  • Emergency services
  • Police and security
  • Industrial facilities
  • First responders

Specifications:

DetectorGeiger-Mueller tube
Dose rate measurement range0.1 µSv/h to 10 Sv/h
Dose rate measurement accuracy±(10+0.0015/Ḣ+0.0015∙Ḣ) %,
where Ḣ is the measured dose rate value in mSv/h
Dose measurement range continuous photon radiationpulsed photon radiation  0.05 µSv to20 Sv 10 µSv to20 Sv
Dose measurement accuracy±20 %
Energy range20 keV to 10 MeV
Energy response relative to 0.662 MeV (137Cs)–60 % (20 keV to 33 keV) –40 % (33 keV to 48 keV) ±30 % (48 keV to 3 MeV) ±50 % (3 MeV to 10 MeV)
Minimum pulse duration of pulsed X-ray radiation1 ms
Memory7500 events
Alarmsvisual, audible, vibration
CommunicationUSB
Power supplyAAA (LR03) battery; external via USB
Battery lifetime (average dose rate < 0.3 µSv/h, active alarms < 20 s / 24 h)≥ 480 hours
Ingress protectionIP65
Drop test1.5 m
Dimensions≤ 71 × 59 × 20 mm
Weight≤ 90 g
Operating conditions
ambient temperature
atmospheric pressure
relative humidity

–20 °C to 50 °C
84 kPa to 106.7 kPa
up to 98 % at 35 °C
RadFlash Electronic Personal Dosimeter

Overview:

RadFlash® X-ray and Gamma Radiation Personal Dosimeter is a miniature electronic dosimeter capable of solving a wide range of personal dose monitoring tasks, including measurement of personal dose equivalent and personal dose equivalent rate of X-ray (continuous and pulsed) and gamma radiation. The RadFlash electronic personal dosimeter gives you immediate feedback, high precision, and unmatched flexibility. It’s the perfect tool for minimizing risk and maximizing confidence.

Operation principle

Continuous monitoring and custom alerts provide immediate, precise feedback, empowering you to react in-the-moment to changes in your exposure environment. The dosimeter is capable of solving a wide range of personal dose monitoring tasks, including measurement of personal dose equivalent Hp(10) and personal dose equivalent rate Ḣp(10) of X-ray (continuous and pulsed) and gamma radiation.

When used with PM530 and PM531 dosimetry software, RadFlash provides assurance that occupational radiation exposures are accurately measured, analyzed, and reported. RadFlash allows for avoiding overexposure by providing real-time measurements and timely warning the wearer that the dose and dose rate thresholds are exceeded. This ensures that specialists can respond quickly and minimize potential health risks.

RadFlash is compatible with the free Polismart® App that delivers radiation exposure analytics and insights to users and enables wireless transfer, analysis, and reporting of the exposure data captured by the dosimeter. Polismart allows for tracking exposure and adjusting dosimeter settings anytime, anywhere, solely with your smartphone.

Features

  • Simple dose reads via smartphone or PC at any time
  • Easy setup via free Polismart® iOS and Android app
  • Clips and a wristband for different wearing options
  • Resistance to cleaning and disinfection agents
  • On-screen, audible and visual (LED) alarms
  • Data transfer via Bluetooth
  • Small and lightweight
  • Single control button
  • Wireless charging

Applications

  • Healthcare workers
    • Interventional radiology
    • Medical physicists
    • Radioisotope labs
    • X-ray diagnostics
  • Customs and border control officers working with X-ray inspection equipment
  • Anyone working under the risk of X–ray and gamma radiation exposure

Specifications:

DetectorGeiger-Mueller tube
Dose rate measurement range0.1 µSv/h to 1 Sv/h
Dose rate measurement accuracy±15 %
Dose measurement range1 µSv to 10 Sv
Dose measurement accuracy±15 %
Energy range15 keV to 1.5 MeV
Energy response relative to 0.662 MeV (137Cs)–29 % to +45 %
Minimum pulse duration of pulsed X-ray radiation2 ms
Memory6000 events
Alarmsvisual, audible
CommunicationBluetooth 4.0 (FCC ID: QOQ13, IC: 5123A-13)
Power supplyrechargeable battery (wireless charger provided)
Battery lifetime≥ 2 months (Bluetooth off, dose rate < 0.3 µSv/h) ≥ 10 days (Bluetooth on, dose rate < 0.3 µSv/h) ≥ 8 hours (Bluetooth on, dose rate < 1 Sv/h)
Ingress protectionIP67
Drop test1.5 m
Dimensions≤ 63 × 50 × 18 mm
Weight≤ 50 g
Operating conditions
ambient temperature
atmospheric pressure
relative humidity
 
–10 °C to 50 °C
84 kPa to 106.7 kPa
up to 98 % at 35 °C

Mobile Detection Systems (MDS)

PoliGate™ Mobile Detection System

Overview:

PoliGate™ MDS is designed for the automatic scanning of fixed or mobile objects to detect illicit trafficking of radioactive substances and materials. The vehicle-integrated system is highly customizable and available in numerous modifications to cater to the specific requirements of customers.

When it comes to securing borders, emergency response and any situation where rapid response is vital, the MDS PoliGate™ MDS is a game-changer. Its mobile design allows for quick deployment at strategic locations, enabling efficient screening of vehicles and cargo for potential radioactive threats.

Operation principle

Integrated Mobile Detection System is intended for:

  • Automatic scanning of fixed or mobile objects, including those located on or within transport vehicles.
  • Temporary control posts of radioactive control aimed to detect illicit trafficking of radioactive substances and materials.
  • Radioactive control at checkpoints that are not equipped with radiation portal monitors or at temporary control posts.
  • Localization and identification of the detected (interdicted) radioactive materials.
  • Environment contamination monitoring both for emergency and routine control.
  • Real-time reporting and transfer of the information obtained from the incident site to the control center for expert support and prompt decision-making.

MDS consists of 3 compartments:

  • Driver’s compartment
  • Operators compartment
  • Technical compartment

DMS is equipped with radiation measurement instruments:

  • Vehicle-based Radiation Portal Monitor for prompt detection of gamma and neutron radiation in stationary and moving objects, such as vehicles, pedestrians and cargo. One or two monitors can be installed in one vehicle (on both sides).
  • PM1703GNA-II Personal Radiation Detector for search, detection and localization of radioactive materials.
  • PM1401K-3 Multipurpose Hand-Held Radiation Monitor/Identifier for identification of the detected (interdicted) radioactive materials.

Features

  • Control zone up to 3 m × 2.5 m (W×H)
  • No vehicle stop is required for measurement
  • Wide gamma energy range from 20 keV to 3 MeV
  • Remote light and audible alarm annunciators in the van
  • Back-up battery providing at least 8 hours of operation
  • Variety of add-on equipment: CCTV, traffic lights, barriers

Applications

  • Customs and border control
  • HAZMAT and CBRNe teams
  • Emergency services
  • Police and security
  • Industrial facilities
  • First responders

Specifications:

Gamma detectorsOrganic plastic scintillator Detector volume is 11000 cm3
Energy range20 keV to 3 MeV
False alarm rate< 1/1000 passages
CommunicationEthernet
Power supplyVehicle power, portable gasoline generator. 12 V built-in rechargeable battery (> 8 h of operation)
Operating conditionsambient temperature:  –30 °C to 50 °C
atmospheric pressure: 88 kPa to 106.7 kPa
relative humidity: up to 98 % at 40 °C

Radiation Portal Monitors (RPMs)

PoliGate™ Deployable Radiation Portal Monitors (RPMs)

PoliGate™ Deployable Radiation Portal Monitor (RPM) is a highly sensitive deployable radiation monitor designed to detect radioactive and nuclear materials transported through a controlled area. The RPM is designed for fast deployment in emergencies and is suitable for indoor and outdoor use.

The RPM is designed for fast deployment in emergencies and is suitable for indoor and outdoor use

Fast deployable RPM is designed to provide a high level of mobility and flexibility, allowing to be used in a variety of settings to screen individuals, vehicles, or cargo at the scene of an incident or in temporary screening situations, such as at major public events.

PoliGate™ Deployable is transported and stored in three transport cases, can be quickly assembled without any specialized tools and provides continuous 24-hour personnel-free operation. The constituent parts of the RPM are the Control Block and Detection Blocks with a laptop with the RPM User Software for advanced operation.

Operation Principle

The RPM is a stationary system comprising independent units connected with the cables. The RPM is transported and stored in three transport cases and can be quickly assembled and disassembled without any specialized tools. 

Once switched on, the RPM provides continuous 24-hour personnel-free operation. In case of power failure, the power supply of the RPM automatically switches to power from the internal battery and is operatable for at least 6 hours. The internal battery is charged automatically when the RPM is connected to a power supply and switched on.

The constituent parts of the RPM are the Control Block and Detection Blocks, accompanied by a set of mounting and connecting elements, and the laptop with the designated user software for the advanced operation of the RPM. The real-time measurements are displayed in an easily readable format, ensuring a quick and accurate assessment of the radiation environment. This data transfer capability ensures that all measurements are logged and stored for comprehensive record-keeping and future reference.

Features

  • No stop of an object is required for measurement
  • Lead shielding for natural background rejection
  • Wide gamma energy range from 20 keV to 3 MeV
  • Local and remote light and audible alarm annunciators
  • Back-up battery providing at least 8 hours of operation
  • Presence detection system (infrared occupancy sensors)
  • Adjustable sensitivity parameters for specific applications
  • Optional video surveillance system

Applications

  • Temporary checkpoints for:

Public events security
Emergency response
Customs and border
Police and security

  • Waste management sites
  • Airports and seaports
  • Industrial facilities

Specifications

Type of registered radiationgamma
DetectorPVT plastic scintillators (5300 cm3)
Energy range30 keV to 3 MeV
Gamma radiation sensitivity78 cps per nSv/h (241Am)
26 cps per nSv/h (137Cs)
12 cps per nSv/h (60Co)

Power90-260 V AC / 14V DC adapter;
12 V built-in rechargeable battery (> 8 h of operation)
PC communicationEthernet, Wi-Fi
Ingress protectionIP65
IP67 in transport cases
Dimensions116×34×16 cm (H×L×W) Detection Block 
30×25×25 cm (H×L×W) Control Block
80×60×50 cm (L×W×D) Transport Case No.1
150×50×30 cm (L×W×D) Transport Case No.2 and No.3

Weight51 kg Detection Block
9 kg Control Block
16 kg (empty), 74 kg (loaded) Transport Case No.1
12 kg (empty), 68 kg (loaded) Transport Case No.2 and No.3
Operating temperature– 30 up to +50 °C
Atmospheric pressure84 to 106.7 kPa
Humidityup to 100 % at 35 °C
PoliGate™ Light Radiation Portal Monitors (RPMs)

PoliGate™ Light series of Radiation Portal Monitors (RPMs) is a high-sensitive fixed system designed for permanent installation and providing continuous radiation detection and monitoring of vehicles, cargo containers, people, or packages. RPMs have a modular design and are available in one-pillar or two-pillar configurations, adaptable height and width according to customer requirements. 

PoliGate™ Light is a simplified series of Polimaster RPMs which is available in a more compact and lightweight design and is not equipped with a neutron detection unit. The RPM is easy to operate and maintain, requires minimal training and is supplied with user-friendly software that provides real-time data and alarms.

Operation Principle

The Polimaster RPMs operate with precision and efficiency, ensuring continuous measurement of radiation levels while allowing seamless data transfer to software for comprehensive analysis and monitoring. Equipped with highly sensitive scintillation detectors, the RPM is capable of continuously detecting and measuring ionizing radiation in real-time. This means that as soon as radiation is present, the device swiftly captures and analyzes the data, providing immediate feedback. Connection to an operator computer or compatible external devices allows to effortlessly transmit the recorded radiation measurements for further analysis and monitoring. The real-time measurements are displayed in an easily readable format, ensuring a quick and accurate assessment of the radiation environment. This data transfer capability ensures that all measurements are logged and stored for comprehensive record-keeping and future reference.

Features

  • Lightweight design
  • Wide gamma energy range from 20 keV to 3 MeV
  • Local and remote light and audible alarm annunciators
  • Back-up battery providing at least 8 hours of operation
  • Presence detection system (infrared occupancy sensors)
  • Adjustable sensitivity parameters for specific applications
  • Optional video surveillance system

Models

Applications

  • Customs and border control
  • Waste management sites
  • Airports and seaports
  • Public events security
  • Nuclear power plants
  • Police and security
  • Industrial facilities
  • Scrap processing

Specifications

Type of registered radiationgamma
Energy range20 keV to 3 MeV
Gamma radiation sensitivity121 cps per nSv/h (241Am)
43 cps per nSv/h (137Cs)
22 cps per nSv/h (60Co)

Powerexternal 90-260V AC 50/60Hz internal battery (12V) with minimum 8 hours lifetime after external power failure 
Ingress protectionIP55
Weight66 kg (one detection block)
Operating temperature-30 °C to 50 °C
Atmospheric pressure84 to 106.7 kPa
PoliGate™ Vehicle Radiation Portal Monitors (RPMs)

PoliGate™ Vehicle series of Radiation Portal Monitors (RPMs) is a high-sensitive fixed system designed for permanent installation and providing continuous radiation detection and monitoring of moving objects.

RPMs have a modular design and are available in one-pillar or two-pillar configurations, adaptable height and width according to customer requirements.

PoliGate™ Vehicle RPM is an essential tool for safeguarding against the potential threat of nuclear materials entering secure areas and can be used for screening trains, trucks, vehicles, cargo containers, luggage and people

The RPM is easy to operate and maintain, requires minimal training and is supplied with user-friendly software that provides real-time data and alarms.

The Polimaster RPMs operate with precision and efficiency, ensuring continuous measurement of radiation levels while allowing seamless data transfer to software for comprehensive analysis and monitoring. 

Equipped with highly sensitive scintillation detectors, the RPM is capable of continuously detecting and measuring ionizing radiation in real-time. This means that as soon as radiation is present, the device swiftly captures and analyzes the data, providing immediate feedback. 

Connection to an operator computer or compatible external devices allows to effortlessly transmit the recorded radiation measurements for further analysis and monitoring. The real-time measurements are displayed in an easily readable format, ensuring a quick and accurate assessment of the radiation environment. This data transfer capability ensures that all measurements are logged and stored for comprehensive record-keeping and future reference.

Features

  • No vehicle stop is required for measurement
  • Lead shielding for natural background rejection
  • Wide gamma energy range from 20 keV to 3 MeV
  • Local and remote light and audible alarm annunciators
  • Back-up battery providing at least 8 hours of operation
  • Presence detection system (infrared occupancy sensors)
  • Adjustable sensitivity parameters for specific applications
  • Optional video surveillance system

Models

Applications

  • Customs and border control
  • Waste management sites
  • Airports and seaports
  • Public events security
  • Nuclear power plants
  • Police and security
  • Industrial facilities
  • Scrap processing
  • Railway

Specifications

Type of registered radiationgamma
Detectororganic plastic scintillator (11000 cm3)
Number of detection units2 gamma detectors
Energy range20 keV to 3 MeV
Gamma radiation sensitivity251 cps per nSv/h (241Am)
57 cps per nSv/h (137Cs)
27 cps per nSv/h (60Co)

Power110 (90-132) V AC or 220 (180-264) V AC, 47-63 Hz;
12 V built-in rechargeable battery (> 8 h of operation)
Power consumptionno more then 120 V•А.
PC communicationEthernet
Ingress protectionIP65
Weight120 kg (one gamma detector) 20 kg (control unit)
Operating temperature–30 °C to 50 °C
Atmospheric pressure84 to 106.7 kPa
Humidityup to 98 % at 40 °C, no moisture
Mean recovery time60 min
Mean service lifetime8 years
Mean time between failures10000 hours
PoliGate™ Pedestrian Radiation Portal Monitors (RPMs)

PoliGate™ Pedestrian RPM is a high-sensitive fixed system designed for permanent installation and monitoring of people or packages for the presence of radioactive materials.

Pedestrian RPM is an essential component of any facility that requires strict security measures, including government buildings, research facilities, and nuclear power plants. 

The compact and ergonomic design of the RPM makes it a convenient solution for use in various applications for screening people, luggage and cargo.

The RPM is easy to operate and maintain, requires minimal training and is supplied with user-friendly software that provides real-time data and alarms.

Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements and can be installed both indoors and outdoors.

Equipped with highly sensitive scintillation detectors, the RPM is capable of continuously detecting and measuring ionizing radiation in real-time. This means that as soon as radiation is present, the device swiftly captures and analyzes the data, providing immediate feedback. 

Connection to an operator computer or compatible external devices allows to effortlessly transmit the recorded radiation measurements for further analysis and monitoring. The real-time measurements are displayed in an easily readable format, ensuring a quick and accurate assessment of the radiation environment. This data transfer capability ensures that all measurements are logged and stored for comprehensive record-keeping and future reference.

Features

  • No stop of an object is required for measurement
  • Lead shielding for natural background rejection
  • Wide gamma energy range from 20 keV to 3 MeV
  • Local and remote light and audible alarm annunciators
  • Back-up battery providing at least 8 hours of operation
  • Presence detection system (infrared occupancy sensors)
  • Adjustable sensitivity parameters for specific applications
  • Optional video surveillance system

Models

Applications

  • Customs and border control
  • Waste management sites
  • Airports and seaports
  • Public events security
  • Nuclear power plants
  • Police and security
  • Industrial facilities
  • Scrap processing
  • Railway stations

Specifications

Type of registered radiationgamma, neutron
Detectorgamma: organic plastic scintillator (6600 cm3)
neutron: 10B/ZnS(Ag) solid-state detector (3He-free)

Number of detection units1 gamma detector
1 neutron detector
Energy range20 keV to 3 MeV
Gamma radiation sensitivity88 cps per nSv/h (241Am)
33 cps per nSv/h (137Cs)
16 cps per nSv/h (60Co)

Neutron radiation sensitivity11250 n/s (252Cf)
Power85-264 V AC, 47-63 Hz;
12 V built-in rechargeable battery (> 8 h of operation)
Alarmsvisual, audible
PC communicationEthernet (cable up to 100 m)
Battery lifetime8 hours (back-up power supply)
Ingress protectionIP65
Weight130 kg (one gamma-neutron detector)
135 kg (total)
Operating temperature–30 °C to 50 °C
Atmospheric pressure84 to 106.7 kPa
Humidityup to 98 % at 40 °C, no moisture
Mean recovery time60 min
Mean service lifetime8 years
Mean time between failures10000 hours